Automatic Implantable Cardioverter Defibrillator (AICD)¸¦ »ðÀÔÇÑ È¯ÀÚ¿¡¼­ ÇÁ·ÎÆ÷Æú, ·¹¹ÌÆ柴ÒÀ» ÀÌ¿ëÇÑ ÁøÁ¤¿ä¹ý ÇÏ Á¦3´ë±¸Ä¡ ¹ßÄ¡ -Áõ·Êº¸°í-
A Case Report of the Patient Implanted with Automatic Implantable Cardioverter Defibrillator (AICD) Subject to 3rd Molar Extraction using Target Controlled Infusion of Propofol and Remifentanil -A Case Report-

´ëÇÑÄ¡°ú¸¶Ãë°úÇÐȸÁö 2009³â 9±Ç 2È£ p.116 ~ p.118

½ÅÅÍÀü(Shin Teo-Jeon) - ¼­¿ï´ëÇб³ Ä¡ÀÇÇдëÇпø Ä¡°ú¸¶Ãë°úÇб³½Ç
¼­±¤¼®(Seo Kwang-Suk) - ¼­¿ï´ëÇб³ Ä¡ÀÇÇдëÇпø Ä¡°ú¸¶Ãë°úÇб³½Ç
±èÇöÁ¤(Kim Hyun-Jeong) - ¼­¿ï´ëÇб³ Ä¡ÀÇÇдëÇпø Ä¡°ú¸¶Ãë°úÇб³½Ç

Abstract

The automatic implantable cardioverter defibrillator (AICD) has been widely used to treat recurrent malignant ventricular arrhythmia. Here, we case report 18 yr old patients implanted with Automatic implantable cardioverter defibrillator (AICD) who underwent surgical extraction under intravenous sedation and discuss the anesthetic implications for surgery.

Å°¿öµå

Implantable defibrillator, Conscious sedation
¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸
µîÀçÀú³Î Á¤º¸
ÇмúÁøÈïÀç´Ü(KCI) 
ÁÖÁ¦ÄÚµå
ÁÖÁ¦¸í(Target field)
¿¬±¸´ë»ó(Population)
¿¬±¸Âü¿©(Sample size)
´ë»ó¼ºº°(Gender)
Áúº´Æ¯¼º(Condition Category)
¿¬±¸È¯°æ(Setting)
¿¬±¸¼³°è(Study Design)
¿¬±¸±â°£(Period)
ÁßÀç¹æ¹ý(Intervention Type)
ÁßÀç¸íĪ(Intervention Name)
Å°¿öµå(Keyword)
À¯È¿¼º°á°ú(Recomendation)
Patient Implanted with Automatic Implantable Cardioverter Defibrillator (AICD) Subject was done to 3rd Molar Extraction using Target Controlled Infusion of Propofol and Remifentanil
¿¬±¸ºñÁö¿ø(Fund Source)