Abstract

Objective: The purpose of this study was to verify the algorithm on bio-signals for a home-health management system.

Methods: A methodological study was done to verify the blood pressure and blood sugar algorithm to deliver tailored patient information. The verifying process was as follows: Step 1; development of the algorithm through a literature review, Step 2; programming the algorithm using Microsoft SQL Server 2005 and Visual Studio 2005, Step 3; Reviewing of the algorithm by examining results from the home-health management system and experts¡¯ evaluation Step 4; evaluating the agreement of the algorithm by comparison between results from the home-health management system and intended results using bio-signal data set, and completion of the algorithm.

Results: Discordance rate between results from the home-health management system and intended results for blood pressure and blood sugar were 5.72% and 2.04%, respectively. Also, discordance rate between results from the home-health management system and experts¡¯ evaluation of blood pressure and blood sugar were 30.38% and 20.41%, respectively. All discordance were revised until all the researchers reached agreement.

Conclusion: The home-health management system with an accurate algorithm on bio-signals can contribute to promote clients¡¯ health and reduce the cost of medical services.

Å°¿öµå

Bio-signal Data, Algorithm, Telehealth (Home-health Management System)
¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸
µîÀçÀú³Î Á¤º¸
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø 
ÁÖÁ¦ÄÚµå
ÁÖÁ¦¸í(Target field)
¿¬±¸´ë»ó(Population)
¿¬±¸Âü¿©(Sample size)
´ë»ó¼ºº°(Gender)
Áúº´Æ¯¼º(Condition Category)
¿¬±¸È¯°æ(Setting)
¿¬±¸¼³°è(Study Design)
¿¬±¸±â°£(Period)
ÁßÀç¹æ¹ý(Intervention Type)
ÁßÀç¸íĪ(Intervention Name)
Å°¿öµå(Keyword)
À¯È¿¼º°á°ú(Recomendation)
The home-health management system with an accurate algorithm on bio-signals can contribute to promote clients¡¯ health and reduce the cost of medical services.