´ëÅð ÀüÀÚ°£ ¿ª»ç»ó °ñÀý¿¡¼ ÀüÀںΠ¾ÈÁ¤È ±Ý¼ÓÆÇÀ» ÀÌ¿ëÇÑ ¾Ð¹Ú °í ³ª»çÀÇ Ä¡·á °á°ú
Results of Use of Compression Hip Screw with Trochanter Stabilizing Plate for Reverse Oblique Intertrochanteric Fracture
´ëÇѰñÀýÇÐȸÁö 2014³â 27±Ç 2È£ p.120 ~ p.126
¹Îº´¿ì(Min Byung-Woo) - °è¸í´ëÇб³ Àǰú´ëÇÐ Á¤Çü¿Ü°úÇб³½Ç
À̰æÀç(Lee Kyung-Jae) - °è¸í´ëÇб³ Àǰú´ëÇÐ Á¤Çü¿Ü°úÇб³½Ç
±è±³¿í(Kim Gyo-Wook) - °è¸í´ëÇб³ Àǰú´ëÇÐ Á¤Çü¿Ü°úÇб³½Ç
¹è±âö(Bae Ki-Choer) - °è¸í´ëÇб³ Àǰú´ëÇÐ Á¤Çü¿Ü°úÇб³½Ç
À̽ÿí(Lee Si-Wook) - °è¸í´ëÇб³ Àǰú´ëÇÐ Á¤Çü¿Ü°úÇб³½Ç
±èµÎÇÑ(Kim Du-Han) - °è¸í´ëÇб³ Àǰú´ëÇÐ Á¤Çü¿Ü°úÇб³½Ç
Abstract
¸ñ Àû: ´ëÅð ÀüÀÚ°£ ¿ª»ç»ó °ñÀýÀÇ ¼ö¼úÀû Ä¡·á¿¡¼ ÀüÀںΠ¾ÈÁ¤È ±Ý¼ÓÆÇÀ» ÀÌ¿ëÇÑ ¾Ð¹Ú °í ³ª»çÀÇ Ä¡·á °á°ú¸¦ ¾Ë¾Æº¸°íÀÚ ÇÏ¿´´Ù.
´ë»ó ¹× ¹æ¹ý: 2000³â 1¿ùºÎÅÍ 2012³â 12¿ù±îÁö ´ëÅð ÀüÀÚ°£ ¿ª»ç»ó °ñÀý·Î ÀÎÇØ ÀüÀںΠ¾ÈÁ¤È ±Ý¼ÓÆÇÀ» ÀÌ¿ëÇÑ ¾Ð¹Ú °í ³ª»ç·Î ¼ö¼úÇÑ È¯ÀÚµé Áß 1³â ÀÌ»ó Ã߽ð¡ °¡´ÉÇÏ¿´´ø 33¿¹¸¦ ´ë»óÀ¸·Î ÇÏ¿´´Ù. ¼ú ÈÄ °ñÀ¯ÇÕ±îÁö ±â°£, ´ëÅð °æ°£°¢ÀÇ º¯È, Áö¿¬ ³ª»çÀÇ È°° Á¤µµ, ¼ú ÈÄ ÇÕº´Áõ µîÀ» Æò°¡ÇÏ¿´´Ù.
°á °ú: ÃÑ 33¿¹ Áß 28¿¹¿¡¼ ¸¸Á·ÇÒ ¸¸ÇÑ Á¤º¹À» ¾ò¾ú´Ù. ¸¸Á·½º·´Áö ¸øÇÑ Á¤º¹À» ¾òÀº 5¿¹¿¡´Â ±â±¸ ÆÄ¼ÕÀÌ 1¿¹, 15 mm ÀÌ»óÀÇ °úµµÇÑ È°°ÀÌ 2¿¹, 10µµ ÀÌ»óÀÇ ³»¹Ýº¯ÇüÀÌ 1¿¹, ³»È¸Àü º¯ÇüÀÌ 1¿¹°¡ ÀÖ¾ú´Ù. ¼ö¼ú ½Ã 10µµ ÀÌ»óÀÇ ³»¹Ýº¯ÇüÀÌ ÀÖ¾ú´ø 1¿¹¿Í ³»È¸Àü º¯ÇüÀ» º¸ÀÎ 1¿¹¿¡¼ ÃßÈÄ ±³Á¤ Àý°ñ¼úÀ» ½ÃÇàÇÏ¿´À¸¸ç °úµµÇÑ È°°À» º¸¿´´ø 1¿¹¿¡¼´Â Àΰø °í°üÀý ¹Ýġȯ¼úÀ» ½ÃÇàÇÏ¿´´Ù. 29¿¹¿¡¼ °ñÀ¯ÇÕÀ» ¾ò¾úÀ¸¸ç °ñÀ¯ÇÕ±îÁö ±â°£Àº Æò±Õ 19.2ÁÖ¿´´Ù.
°á ·Ð: ´ëÅð ÀüÀÚ°£ ¿ª»ç»ó °ñÀý¿¡¼ ÀüÀںΠ¾ÈÁ¤È ±Ý¼ÓÆÇÀ» ÀÌ¿ëÇÑ ¾Ð¹Ú °í ³ª»ç´Â À¯¿ëÇÑ Ä¡·á ¹æ¹ýÀÌ µÉ ¼ö ÀÖ´Ù. ±×·¯³ª ¼º°øÀûÀÎ Ä¡·á¸¦ À§Çؼ´Â Á¤È®ÇÑ °ñÀýÀÇ Á¤º¹°ú ÀûÀýÇÑ À§Ä¡¿¡ ±â±¸ÀÇ »ðÀÔÀÌ ¹Ýµå½Ã ÇÊ¿äÇÒ °ÍÀ¸·Î »ý°¢µÈ´Ù.
Purpose: The aim of this study was to analyze the use of a compression hip screw with a trochanter stabilizing plate for treatment of reverse oblique intertrochanteric fractures.
Materials and Methods: We reviewed the results of 33 cases of reverse oblique intertrochanteric fracture treated with a compression hip screw with a trochanter stabilizing plate from January 2000 to December 2012 which were followed-up for more than one year. We evaluated postoperative bone union period, change of neck-shaft angle, sliding of hip screw, and other complications.
Results: Of 33 patients, satisfactory reduction was achieved in 28 patients. Five patients had an unsatisfactory reduction, with two cases of excessive screw sliding, one of broken metal, one of varus deformity, and one of internal rotation deformity. We performed corrective osteotomy in varus and internal rotation deformity and partial hip replacement in a case of ex-cessive screw sliding. Bone union was achieved in 29 patients, and the average bone union period was 19.2 weeks.
Conclusion: We consider that a compression hip screw with a trochanteric stabilized plate is a good option for treatment of reverse oblique intertrochanteric femoral fractures. However, adequate fracture reduction and ideal implant placement are a basic necessity for successful treatment.
Ű¿öµå
´ëÅð ÀüÀÚ°£ ¿ª»ç»ó °ñÀý, ¾Ð¹Ú °í ³ª»ç, ÀüÀںΠ¾ÈÁ¤È ±Ý¼ÓÆÇ
Intertrochanteric fracture, Reverse oblique, Compression hip screw, Trochanter stabilizing plate
KMID :
0386420140270020120
¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸
µîÀçÀú³Î Á¤º¸
À¯È¿¼º°á°ú(Recomendation)