À¥ ±â¹Ý Àΰø½ÉÀå ¸ð´ÏÅ͸µ ½Ã½ºÅÛÀÇ ¼³°è¿Í ±¸Çö
Design ana Implementation of the Web-based Monitoring System for an Artificial Heart

ÀÇ°øÇÐȸÁö 2002³â 23±Ç 2È£ p.131 ~ p.137

Á¤ÁøÇÑ(Chung Jin-Han) - ¼­¿ï´ëÇб³ ´ëÇпø Çùµ¿°úÁ¤ ÀÇ¿ë»ýü°øÇÐ
ÀÌÁöÈÆ(Lee Ji-Hoon) - ¼­¿ï´ëÇб³ ÀÇ°ú´ëÇÐ ÀÇ°øÇб³½Ç
ÃÖÀç¼ø(Chol Jae-Soon) - (ÁÖ)¹ÙÀÌ¿À¸Þµå·¦
¹Îº´±¸(Min Byoung-Goo) - ¼­¿ï´ëÇб³ ÀÇ°ú´ëÇÐ ÀÇ°øÇб³½Ç

Abstract

À̵¿ ÀÛµ¿±âÇü Àΰø½ÉÀåÀÇ ¿ø°Ý ¸ð´ÏÅ͸µÀ» À§ÇÑ ½ÃÆ®ÅÛÀ» ¼³°è, ±¸ÇöÇÏ¿´´Ù. µ¿¹° ½ÇÇèÀ̳ª ȯÀÚ¿¡ÀÇ ÀÓ»ó ½ÇÇèÈÄ Àΰø½ÉÀå µ¿ÀÛ »óȲ¿¡ ´ëÇÑ ¿ø°Ý ¸ð´ÏÅ͸µÀº ÇʼöÀûÀÌ´Ù. º» ³í¹®¿¡¼­´Â ´ã´çÀÚ°¡ ȯÀڷκÎÅÍ ¸Ö¸® ¶³¾îÁø°÷¿¡ ÀÖÀ» ¶§¿¡µµ ÀÎÅͳÝÀ» ÅëÇØ °£ÆíÇÏ°Ô Àΰø½ÉÀåÀÇ µ¿ÀÛ »óȲ°ú Ç÷·ù¿ªÇÐ Á¤º¸¸¦ È®ÀÎÇÒ ¼ö ÀÖ´Â ½Ã½ºÅÛÀ» Á¦¾ÈÇÏ¿© ±× ¼º´ÉÀ» È®ÀÎÇÏ¿´´Ù. ±âÁ¸ÀÇ ½Ã½ºÅÛ°ú ½±°Ô ¿¬°áÇÏ¿© »ç¿ëÇÒ¼ö ÀÖµµ·Ï, ¶Ç ½¬¿î °ü¸®¿Í ±â´É Çâ»óÀ» À§ÇÏ¿© COM(Component Object Model) ±â¼ú ±â¹ÝÀÇ ÄÞÆ÷³ÍÆ® ¸ðµâ·Î µ¥ÀÌÅÍ Àü¼Û ºÎºÐÀ» ±¸ÇöÇÏ¿´°í, ¹ü¿ëÀÇ ºê¶ó¿ìÀú¸¦ ÀÌ¿ëÇÏ¿© ÀÎÅͳݿ¡ ¿¬°á, È®ÀÎÅä·Ï ÀÚ¹Ù ¾ÖÇø´À¸·Î ÀÌ¿ëÇÏ¿© ½ÇÇàµÇµµ·Ï ÇÏ¿´´Ù. ¶ÇÇÑ Á¤ÇØÁø ·ê¿¡ µû¶ó ÆÇ´ÜÇÏ¿© Àΰø ½ÉÀåÀÇ ÀÌ»ó µ¿À۽à °ü¸®ÀÚ¿¡°Ô ¾Ë·ÁÁÖµµ·Ï ÇÏ¿´´Ù. ±¸ÇöµÈ ½Ã½ºÅÛÀ» 1°³¿ù ÀÌ»ó »ýÁ¸ÇÏ´Â µ¿¹°¿¡ Àû¿ëÇÏ¿© º» °á°ú ¾Æ¹«·± ¹®Á¦¾øÀÌ Á¤»ó µ¿ÀÛÇÔÀ» È®ÀÎÇÏ¿´´Ù.

The remote monitoring system including hemodynamic information and pump status of the implanted animal could be helpful during the in vivo experiment of clinical trial for an artificial heart implantation. In order to monitor the course of the in vivo experiment continuously and anywhere, web-based remote monitoring system was developed, which can monitor pressures(AoP, LAP, RAP, PAP) and flow information as well as the pump operating conditions. The system consists of data sending, storing, viewer part. The data sending part was constructed using component object model and the viewer part was constructed using the Java applet. In addition, the dialog box was introduced to communicate each other instantly and the alarming function was also introduced when the hemodynamic values were out of the desired ranges. The developed remote monitoring wywtem was applied during the in vivo experiment of the BVAD (Bi-ventricular Assist Device) implantation for 1 month and showed designed work without failure.

Å°¿öµå

Remote Monitoring, Alarm Message, Moving-actuator type VAD(AnyHeart)
¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸
µîÀçÀú³Î Á¤º¸
ÁÖÁ¦ÄÚµå
ÁÖÁ¦¸í(Target field)
¿¬±¸´ë»ó(Population)
¿¬±¸Âü¿©(Sample size)
´ë»ó¼ºº°(Gender)
Áúº´Æ¯¼º(Condition Category)
¿¬±¸È¯°æ(Setting)
¿¬±¸¼³°è(Study Design)
¿¬±¸±â°£(Period)
ÁßÀç¹æ¹ý(Intervention Type)
ÁßÀç¸íĪ(Intervention Name)
Å°¿öµå(Keyword)
À¯È¿¼º°á°ú(Recomendation)
The developed remote monitorung system was applied to animals for one month and showed designed work without failure.
¿¬±¸ºñÁö¿ø(Fund Source)
±Ù°Å¼öÁØÆò°¡(Evidence Hierarchy)
ÃâÆdz⵵(Year)
Âü¿©ÀúÀÚ¼ö(Authors)
´ëÇ¥ÀúÀÚ
DOI
KCDÄÚµå
ICD 03
°Ç°­º¸ÇèÄÚµå