À¯¼öÁ¤Ã¼ ¾È³»ÈĹ添Áî»ðÀÔ¼ú ÈÄ ¸Á¸·½Å°æ¼¶À¯Ãþ µÎ²² ÃøÁ¤°ªÀÇ º¯È
The Change of Retinal Nerve Fiber Layer Thickness after Posterior Chamber Phakic Intraocular Lens Implantation
´ëÇѾȰúÇÐȸÁö 2014³â 55±Ç 5È£ p.702 ~ p.710
ÀÌÅÂÈñ(Lee Tae-Hee) - Àü³²´ëÇб³ Àǰú´ëÇÐ ¾È°úÇб³½Ç
¹ÚÁ¤¿ø(Park Jung-Won) - Àü³²´ëÇб³ Àǰú´ëÇÐ ¾È°úÇб³½Ç
Á¤¼¼Çü(Jeong Se-Hyeong) - Àü³²´ëÇб³ Àǰú´ëÇÐ ¾È°úÇб³½Ç
¹Ú»ó¿ì(Park Sang-Woo) - Àü³²´ëÇб³ Àǰú´ëÇÐ ¾È°úÇб³½Ç
Abstract
¸ñÀû: À¯¼öÁ¤Ã¼ ¾È³»ÈĹ添Áî »ðÀÔ¼úÀ» ½ÃÇà ¹ÞÀº ȯÀÚ¿¡¼ ºû°£¼·´ÜÃþÃÔ¿µ(optical coherence tomography, OCT)À» ÀÌ¿ëÇÏ¿© ¼ö¼ú ÀüÈÄÀÇ ¸Á¸·½Å°æ¼¶À¯Ãþ µÎ²²ÀÇ ÃøÁ¤°ªÀÇ º¯È ¾ç»óÀ» ºÐ¼®Çϰí ÀÌ¿Í °ü·ÃµÈ ÀÎÀÚ¿¡ ´ëÇØ ºÐ¼®ÇϰíÀÚ ÇÏ¿´´Ù.
´ë»ó°ú ¹æ¹ý: À¯¼öÁ¤Ã¼ ¾È³»ÈĹ添Áî »ðÀÔ¼úÀ» ½ÃÇà ¹Þ°í 1°³¿ù ÀÌ»ó °æ°ú°üÂûÀÌ °¡´ÉÇÏ¿´´ø 40¸í 40¾È¿¡ ´ëÇÏ¿© Àǹ«±â·ÏÀ» ÈÄÇâÀûÀ¸ ·Î ºÐ¼®ÇÏ¿´´Ù. ½ºÆåÆ®·³¿µ¿ª ºû°£¼·´ÜÃþÃÔ¿µ±â¸¦ ÀÌ¿ëÇÑ ±º(A±º) 20¸í 20¾È°ú ½Ã°£¿µ¿ª ºû°£¼·´ÜÃþÃÔ¿µ±â¸¦ ÀÌ¿ëÇÑ ±º(B±º) 20¸í 20¾È¿¡¼ ¼ö¼ú ÀüÈÄÀÇ »óÃø, ÇÏÃø, ºñÃø, ÀÌÃø ¹× Æò±Õ ¸Á¸·½Å°æ¼¶À¯Ãþ µÎ²²ÀÇ ÃøÁ¤°ªÀÇ º¯È¸¦ ÃøÁ¤ÇÏ°í ±× º¯È¸¦ ¾Ë¾Æº¸°íÀÚ ÇÏ¿´´Ù.
°á°ú: µÎ ±ºÀÇ ¸Á¸·½Å°æ¼¶À¯ÃþÀÇ Æò±Õ µÎ²²¿Í A±ºÀÇ ÀÌÃø, ÇÏÃø, »óÃø, B±ºÀÇ ÇÏÃø, »óÃøÀÇ ¸Á¸·½Å°æ¼¶À¯Ãþ µÎ²²ÀÇ ÃøÁ¤°ªÀÇ º¯È´Â ¼ö¼ú Àü°ú ºñ±³ÇÏ¿© ¼ö¼ú ÈÄ À¯ÀÇÇÑ Áõ°¡¾ç»óÀ» º¸¿´À¸³ª(p£¼0.05), ÀÌ´Â ¼ö¼ú Àü ±¸¸é´ëÀÀÄ¡, ¼ö¼ú ÀüÈÄÀÇ ±¸¸é´ëÀÀÄ¡ º¯È·® ¹× »ðÀÔµÈ ·»Áî µµ¼ö¿Í À¯ÀÇÇÑ »ó°ü°ü°è¸¦ º¸ÀÌÁö´Â ¾Ê¾Ò´Ù.
°á·Ð: À¯¼öÁ¤Ã¼ ¾È³»ÈĹ添Áî »ðÀÔ¼ú ÈÄ ºû°£¼·´ÜÃþÃÔ¿µÀ» ÀÌ¿ëÇÑ ¸Á¸·½Å°æ¼¶À¯Ãþ µÎ²²ÀÇ ÃøÁ¤°ªÀÇ º¯È¸¦ ÃøÁ¤ ½Ã ¼ö¼ú Àü¿¡ ºñÇØ µÎ²®°Ô ÃøÁ¤µÉ ¼ö ÀÖ¾î °á°ú ÇØ¼®¿¡ ÁÖÀǸ¦ ¿äÇÑ´Ù.
Purpose: In the present study we evaluated the changes of measured retinal nerve fiber layer (RNFL) thickness using optical coherence tomography (OCT) after phakic intraocular lens (implantable collamer lens, ICL) implantation and analyzed the factors correlated with the changes of measured RNFL thickness.
Methods: Forty eyes of 40 patients (Group A: 20 patients using spectral domain OCT and Group B: 20 patients using time domain OCT) who underwent ICL implantation were included in this study. RNFL thickness was measured 1 week before surgery and 1 month postoperatively using OCT. The changes of measured RNFL thickness and the correlation between patients¡¯ data were analyzed.
Results: The postoperative measured RNFL thickness of the average, inferior, temporal, and superior quadrants were increased compared to preoperative measured RNFL thickness in Group A. Group B had similar results in the average, inferior, and superior quadrants (p < 0.05). However, the postoperative changes of RNFL measurements were not correlated with the preoperative spherical equivalent, the degree of spherical equivalent change and diopters of implanted lens (p > 0.05).
Conclusions: The measured RNFL thickness after ICL implantation may increase compared to the preoperative value. Caution should be taken when interpreting the RNFL thickness values measured by OCT in patients with myopia who undergo ICL implantation.
Ű¿öµå
Optical coherence tomography, Phakic intraocular lens implantation, Retinal nerve fiber layer