Formula Comparison for Intraocular Lens Power Calculation Using IOL Master and Ultrasound for the ZCB00 IOL

´ëÇѾȰúÇÐȸÁö 2014³â 55±Ç 4È£ p.527 ~ p.233

½Åµ¿ÈÆ(Shin Dong-Hoon) - ¼º±Õ°ü´ëÇб³ Àǰú´ëÇÐ »ï¼º¼­¿ïº´¿ø ¾È°úÇб³½Ç
ÀÓµ¿Èñ(Lim Dong-Hui) - ¼º±Õ°ü´ëÇб³ Àǰú´ëÇÐ »ï¼º¼­¿ïº´¿ø ¾È°úÇб³½Ç
À¯ÀÚ¿µ(You Ja-Young) - ¼º±Õ°ü´ëÇб³ Àǰú´ëÇÐ »ï¼º¼­¿ïº´¿ø ¾È°úÇб³½Ç
Á¤ÀÇ»ó(Chung Eui-Sang) - ¼º±Õ°ü´ëÇб³ Àǰú´ëÇÐ »ï¼º¼­¿ïº´¿ø ¾È°úÇб³½Ç
Á¤Å¿µ(Chung Tae-Young) - ¼º±Õ°ü´ëÇб³ Àǰú´ëÇÐ »ï¼º¼­¿ïº´¿ø ¾È°úÇб³½Ç

Abstract

¸ñÀû: Tecnis ZCB00 Àΰø¼öÁ¤Ã¼ µµ¼ö °áÁ¤À» À§ÇØ ºÎºÐ°áÇÕ°£¼·°è¿Í ÃÊÀ½ÆÄ¸¦ ÀÌ¿ëÇØ »êÃâÇÑ ¿¹ÃøÄ¡ °£¿¡ Â÷À̸¦ º¸ÀÌ´Â °æ¿ì°¡ ÀÖ´Ù. ÀÌ·¯ÇÑ Â÷À̸¦ Åë°èÀûÀ¸·Î ºÐ¼®Çϰí, Á¤È®ÇÑ µµ¼ö ¼±Åÿ¡ ´ëÇØ ¾Ë¾Æº¸°íÀÚ ÇÏ¿´´Ù.

´ë»ó°ú ¹æ¹ý: ÇѰ¡Áö Àΰø¼öÁ¤Ã¼·Î(AMO Tecnis ZCB00) ¹é³»Àå ¼ö¼úÀ» ¹ÞÀº 170¾ÈÀ» ´ë»óÀ¸·Î ¼ú Àü SRK/T°ø½ÄÀ» ÀÌ¿ëÇÏ¿© °è»êÇÑ ºÎºÐ°áÇÕ°£¼·°è¿Í ÃÊÀ½ÆÄÀÇ ¿¹»ó ±¼Àý·Â »çÀÌÀÇ Â÷À̸¦ ºÐ¼®Çϰí, ¿µÇâÀ» ÁÖ´Â ¿äÀÎÀÌ ÀÖ´ÂÁö ºÐ¼®ÇÏ¿´´Ù. ¼úÀü ¿¹»ó ±¼Àý·Â°ú ¼ö¼ú 3°³¿ù ÈÄ ½ÇÁ¦ ±¼Àý·ÂÀÇ ºñ±³¸¦ ÅëÇØ, µÎ ±â±â »çÀÌÀÇ µµ¼ö ¿¹ÃøÄ¡ Â÷À̰¡ Å« °æ¿ì, ¾î¶² ¹æ¹ý¿¡ ±Ù°ÅÇÏ¿© µµ¼ö¸¦ ¼±ÅÃÇÏ´Â °ÍÀÌ Á¤È®ÇÑÁö ¾Ë¾Æº¸¾Ò´Ù.

°á°ú: ZCB00ÀÇ °æ¿ì ºÎºÐ°áÇÕ°£¼·°è ¹× ÃÊÀ½ÆÄ·Î »êÃâÇÑ ¿¹Ãø ±¼Àý·Â »çÀÌ¿¡ À¯ÀÇÇÑ Â÷À̰¡ ÀÖ¾ú´Ù. µÎ ±â±â °£ µµ¼ö ¿¹ÃøÄ¡¿¡ Â÷À̸¦ °¡Á®¿À´Â ƯÁ¤ ¿äÀÎÀº ¾ø¾ú´Ù. ºÎºÐ°áÇÕ°£¼·°è ¹× ÃÊÀ½ÆÄ·Î ¿¹ÃøÇÑ Àΰø¼öÁ¤Ã¼ µµ¼ö °£ÀÇ Â÷À̰¡ Å« °æ¿ì¿¡´Â, ºÎºÐ°áÇÕ°£¼·°è°¡ ÃÊÀ½ÆÄ ¹æ½Ä¿¡ ºñÇØ Á¤È®ÇÏ¿´´Ù. ÀÌ ¶§ IOL Master¢çÀÇ ¼¼ °ø½Ä (SRK/II, SRK/T, Haigis) »çÀÌ¿¡´Â Åë°èÀûÀ¸·Î À¯ÀÇÇÑ Â÷À̰¡ ¾ø¾ú´Ù. ÃÊÀ½ÆÄ·Î °è»êÇÑ °ªÀ» ±âÁØÀ¸·Î µµ¼ö¸¦ ¼±ÅÃÇÒ °æ¿ì ¼ú ÈÄ ¿ø½ÃÆíÀ§¸¦ º¸¿´´Ù.

°á·Ð: ZCB00 Àΰø¼öÁ¤Ã¼¿¡¼­ ºÎºÐ°áÇÕ°£¼·°è ¹× ÃÊÀ½ÆÄ¸¦ ÀÌ¿ëÇØ ÃøÁ¤ÇÑ Àΰø¼öÁ¤Ã¼ ±¼Àý¿¹Ãø¿¡ Å« Â÷À̸¦ º¸ÀÌ´Â °æ¿ì°¡ ÀÖÀ¸¸ç, À̶§¿¡´Â ºÎºÐ°áÇÕ°£¼·°è¸¦ ¹ÙÅÁÀ¸·Î µµ¼ö¸¦ ¼±ÅÃÇÏ´Â °ÍÀÌ Á¤È®ÇÏ´Ù.
Purpose: To evaluation the accuracy of the IOL power calculation formulae measured by IOL Master¢ç and applanation ultrasonography for the Tecnis ZCB00 IOL

Methods: We performed a retrospective study of 170 eyes in 121 patients who underwent cataract surgery in our hospital with AMO Tecnis ZCB00 IOL.s. The SRK/T formula was used to predict the patient¡¯s implanted IOL power. Differences in the predicted refractive errors between IOL Master¢ç and ultrasonography were analyzed and factors attributed to the differences were also analyzed. Three months after cataract surgery, mean numeric error and mean absolute error were analyzed.

Results: SRK/II and SRK/T formulas calculated using ultrasonography showed differences compared to the same formulas calculated using IOL Master¢ç, in which hyperopic shift was also demonstrated. No definite factor was attributed to the differences between the 2 methods. Although the 3 formulas of IOL Master¢ç showed no significant difference in refractive errors, the SRK/T formula calculated using IOL Master¢ç showed the least mean absolute and numeric errors.

Conclusions: IOL Master¢ç is considered more suitable when determining proper AMO Tecnis ZCB00 IOL power in cataract surgery. The hyperopic shift should be considered when calculating the IOL power using only ultrasonography.

Ű¿öµå

Intraocular lens power calculation, IOL Master¢ç, Ultrasound (A-scan), ZCB00
¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸
µîÀçÀú³Î Á¤º¸
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø 
ÁÖÁ¦ÄÚµå
ÁÖÁ¦¸í(Target field)
¿¬±¸´ë»ó(Population)
¿¬±¸Âü¿©(Sample size)
´ë»ó¼ºº°(Gender)
Áúº´Æ¯¼º(Condition Category)
¿¬±¸È¯°æ(Setting)
¿¬±¸¼³°è(Study Design)
¿¬±¸±â°£(Period)
ÁßÀç¹æ¹ý(Intervention Type)
ÁßÀç¸íĪ(Intervention Name)
Ű¿öµå(Keyword)
À¯È¿¼º°á°ú(Recomendation)
¿¬±¸ºñÁö¿ø(Fund Source)
±Ù°Å¼öÁØÆò°¡(Evidence Hierarchy)
ÃâÆÇ³âµµ(Year)
Âü¿©ÀúÀÚ¼ö(Authors)
´ëÇ¥ÀúÀÚ
DOI
KCDÄÚµå
ICD 03
°Ç°­º¸ÇèÄÚµå