Multiphasic Dynamic Computed Tomography Evaluation of Liver Tissue Perfusion Characteristics Using the Dual Maximum Slope Model in Patients With Cirrhosis and Hepatocellular Carcinoma: A Feasibility Study.

Lee, Dong Ho; Lee, Jeong Min; Klotz, Ernst; Han, Joon Koo
Investigative radiology
2016Jul ; 51 ( 7 ) :430-4.
저자 상세정보
Lee, Dong Ho -
Lee, Jeong Min -
Klotz, Ernst -
Han, Joon Koo -
ABSTRACT
OBJECTIVE: The aim of this study was to investigate the feasibility of multiphasic dynamic computed tomography (CT) scans in providing liver tissue perfusion characteristics using the dual maximum slope model in patients with liver cirrhosis and hepatocellular carcinoma (HCC). MATERIALS AND

METHODS: With institutional review board approval and acquisition of informed consent, we retrospectively analyzed the prospectively collected perfusion CT (PCT) data of 36 patients enrolled in a prospective clinical trial for pretherapeutic assessment of HCC. To obtain perfusion parameters including arterial liver perfusion (ALP), portal venous perfusion (PVP), and the hepatic perfusion index (HPI), 5-phase dynamic CT data sets with triple arterial phases including peak aortic and splenic enhancement information were selected from the PCT data sets. The PCT and 5-phase dynamic CT data sets extracted from the PCT data were analyzed using dedicated perfusion software based on the dual maximum slope model. Comparisons between the perfusion parameters of each method were performed using Wilcoxon signed rank test and intraclass correlation coefficients.

RESULTS: The extraction of liver perfusion parameters from 5-phase dynamic CT scans was feasible using the dual maximum slope model, and no significant differences were observed between perfusion parameters obtained from 5-phase dynamic CT and from PCT in the liver parenchyma (ALP, P = 0.137; PVP, P = 0.110; HPI, P = 0.793) and in HCCs (ALP, P = 0.162; HPI, P = 0.131). Regarding intraclass correlation coefficients, excellent agreement was observed between perfusion parameters obtained using 5-phase dynamic CT and from PCT in both the liver parenchyma (ALP, 0.793; PVP, 0.831; HPI, 0.934) and in HCCs (ALP, 0.889; HPI, 0.943).

CONCLUSIONS: The extraction of liver perfusion parameters from 5-phase dynamic CT scans was feasible using the dual maximum slope model and provided comparable values to those obtained from PCT.
multiphasic dynamic CT, perfusion CT, liver tissue perfusion, dual maximum slope model
링크

주제코드
주제명(Target field)
연구대상(Population)
연구참여(Sample size)
대상성별(Gender)
질병특성(Condition Category)
연구환경(Setting)
연구설계(Study Design)
연구기간(Period)
중재방법(Intervention Type)
중재명칭(Intervention Name)
키워드(Keyword)
유효성결과(Recomendation)
The extraction of liver perfusion parameters from 5-phase dynamic CT scans was feasible using the dual maximum slope model, and no significant differences were observed between perfusion parameters obtained from 5-phase dynamic CT and from PCT in the liver parenchyma (ALP, P = 0.137; PVP, P = 0.110; HPI, P = 0.793) and in HCCs (ALP, P = 0.162; HPI, P = 0.13.
연구비지원(Fund Source)
근거수준평가(Evidence Hierarchy)
출판년도(Year)
참여저자수(Authors)
대표저자
DOI
10.1097/RLI.0000000000000247
KCD코드
ICD 03
건강보험코드