Defibillator electrogram T wave alternans as a predictor of spontaneous ventricular tachyarrhythmias in defibrillator recipients.

Kim, Jin Won; Pak, Hui-Nam; Park, Jae Hyung; Nam, Gi-Byoung; Kim, Sook Kyoung; Lee, Hyun Soo; Jang, Jin Kun; Choi, Jong Il; Kim, Young-Hoon
Circulation journal : official journal of the Japanese Circulation Society
2009Jan ; 73 ( 1 ) :55-62.
ÀúÀÚ »ó¼¼Á¤º¸
Kim, Jin Won -
Pak, Hui-Nam -
Park, Jae Hyung -
Nam, Gi-Byoung -
Kim, Sook Kyoung -
Lee, Hyun Soo -
Jang, Jin Kun -
Choi, Jong Il -
Kim, Young-Hoon -
ABSTRACT
BACKGROUND: Although T wave alternans (TWA) and the T wave peak-to-end (Tpte) interval are associated with vulnerability to ventricular tachyarrhythmia (VT), no previous reports have demonstrated that TWA immediately precedes spontaneous VT in the human ambulatory setting. METHODS AND

RESULTS: Stored electrograms from the implantable cardioverter defibrillators (ICD) of 74 patients (59 males, 55.3+/-12.2 years) were analyzed. TWA (DeltaT amplitude), Tpte interval, QT interval, and RR intervals were measured from magnified digital images immediately before spontaneous VT (VT(Clinical); n=73), or immediately after ICD shocks during artificially-induced VT (VT(Induced); n=74) or inappropriate shocks (Shock(Inapp); n=6). (1) TWA was significantly greater in VT(Clinical) than VT(Induced) (P<0.01) or Shock(Inapp) (P<0.001), but Tpte was not (P=NS). (2) In the VT(Clinical) group, TWA was significantly greater in patients with ischemic VT than in those with non-ischemic cardiomyopathy or idiopathic VF (P<0.05). (3) In the same patient, the TWA for VT(Clinical) was significantly greater than that for VT(Induced) (P<0.01). CONCLUSION: TWA measured from ICD electrograms is significantly greater immediately before spontaneous VT than immediately after inappropriate shocks or shocks during induced VT. These findings indicate that repolarization alternans plays an important role in the induction of VT in humans.
Implantable cardioverter defibrillator; T wave alternans; Ventricular tachycardia
MESH
Adult, Aged, Brugada Syndrome/physiopathology/therapy, Cardiomyopathy, Hypertrophic/physiopathology/therapy, *Defibrillators, Implantable, *Electrocardiography, *Electrophysiologic Techniques, Cardiac, Female, Follow-Up Studies, Heart Conduction System/physiopathology, Humans, Long QT Syndrome/physiopathology/therapy, Male, Middle Aged, Predictive Value of Tests, Tachycardia, Ventricular/*diagnosis/*physiopathology/therapy
¸µÅ©

ÁÖÁ¦ÄÚµå
ÁÖÁ¦¸í(Target field)
¿¬±¸´ë»ó(Population)
¿¬±¸Âü¿©(Sample size)
´ë»ó¼ºº°(Gender)
Áúº´Æ¯¼º(Condition Category)
¿¬±¸È¯°æ(Setting)
¿¬±¸¼³°è(Study Design)
¿¬±¸±â°£(Period)
ÁßÀç¹æ¹ý(Intervention Type)
ÁßÀç¸íĪ(Intervention Name)
Å°¿öµå(Keyword)
À¯È¿¼º°á°ú(Recomendation)
T wave alternans (TWA) measured from ICD electrograms is significantly greater immediately before spontaneous VT than immediately after inappropriate shocks or shocks during induced VT.
¿¬±¸ºñÁö¿ø(Fund Source)
±Ù°Å¼öÁØÆò°¡(Evidence Hierarchy)
ÃâÆdz⵵(Year)
Âü¿©ÀúÀÚ¼ö(Authors)
´ëÇ¥ÀúÀÚ
DOI
http://doi.org/10.1253/circj.CJ-08-0311
KCDÄÚµå
ICD 03
°Ç°­º¸ÇèÄÚµå